Micro Spectrophotometer TRMS-605
Micro Spectrophotometer TRMS-605 works as a new type of full-wavelength spectrophotometer. With a mode of USB output or network transfer data, having with an electronic manual. It comes with a Light source as long life pulsed xenon flash lamp. With a pre-installation storage spacing of 32 GB. With a Minimum, a sample volume of the cuvette is 20 μl, with a wavelength range of 190 to 850 nm.
| Wavelength Range | 190 to 850 nm |
|---|---|
| Wavelength Accuracy | ± 1nm |
| Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
| Repeatability | <± 0.5 nm |
| Light Path | 1 mm, 0.05 mm (optical path automatic conversion) |
| Absorbance Accuracy | 1% (0.76 absorbance at 350 nm) |
| Absorbance Range | 0.002 to 300Abs (equivalent to 10mm path length) |
| sample volume Requirements | 0.3 to 2 μl |
| Cuvette Specifications | 1 mm, 2 mm, 5 mm, 10 mm |
| (optical path) | |
| Min sample volume of the cuvette | 20 μl |
| The minimum height of the cuvette sample | 5 mm |
| Temperature Control | 4 to 42 ℃ thermostat adjustable temperature error <± 0.5 ℃ |
| Nucleic Acid measurement range | 0.2 to 37500 mg / μl (sa DNA) |
| Protein measurement range | 0.01 to 1120 mg / ml (BSA) |
| Sample measurement time | less than 3s |
| Sample base material | stainless steel and quartz fiber |
| Light Source | long life pulsed xenon flash lamp |
| Detector | 2048(CMOS) element linear silicide CCD array |
- Users can save measurement result data and custom methods directly in spreadsheet mode
- 32GB of storage space is pre-installed
- Integrated fiber to prevent fibre breakage due to external force collision, which results in chaotic measurement results
- There is no need to warm up, start testing whenever you want
- Built-in Win10 system, built-in 7-inch high-definition display, full touch operation
- Stainless steel and quartz fiber is used for the platform
- Using a liquid column to identify abnormal function
- The built-in Bluetooth and WIFI allow for remote operation and wireless printing of results
- Two USB ports that can connect to a variety of devices such as mice, keyboards, desktop computers, and so on
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Micro Spectrophotometer TRMS-604
- Wavelength Range : 190 to 850 nm
- Wavelength Accuracy : ± 1 nm
- Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
- Repeatability : <± 0.5 nm
Micro-Spectrophotometer TRMS-601
- Light Path : 1mm
- sample Volume : 1 to 2μL
- Detection Range : 190 to 850 nm
- Wavelength Range : 190 to 1100 nm
Micro-spectrophotometer TRMS-602
- Optical Path : 1/0.5/0.05 mm automatic conversion
- Optical Range : 190 to 1100 nm
- Sample Volume : 0.3 to 2.0 μl
- Light Source : Long-life Xenon lamp
Micro-spectrophotometer TRMS-603
- Wavelength scanning Range : 190 to 850 nm
- Wavelength Accuracy : ±1 nm
- Optical Path : 1/0.5/0.05 mm automatic conversion
- Optical Range : 190 to 1100 nm
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Atomic Absorption Spectrophotometer TRAS-601
- Wavelength Range : 190 to 900 nm
- Wavelength Accuracy : £ ±0.5 nm
- Wavelength Repeatability : £ 0.3 nm (single direction)
- Spectrum Bandwidth : 0.2 nm, 0.4 nm, 0.7nm, 1.4 nm, 2.4 nm, 5.0 nm
Atomic Absorption Spectrophotometer TRAS-701
- Wavelength range : 190 to 900 nm
- Spectral bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
- Accuracy of the wavelength : ±0.15 nm
- Receptivity of the wavelength : ≤0.04 nm
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Energy Dispersion X-ray Fluorescence Spectrometer TRXS-601
- Analysis Principle : Energy-dispersive X-ray fluorescence analysis
- Element Measuring Range : Any element from Na(11)-U(92)
- Minimum Measuring Limit : Cd/Hg/Br/Cr/Pb≤2 ppm
- Sample Shape : Arbitrary size, any irregular shape
Fluorescence Spectrophotometer TRFS-601
- Exciting Optical Filters : Interface optical filter (10 nm bandwidth)
- Wavelength : 365 nm
- Emission Monochromatic : C-T diffraction grating (EM 200 to 900 nm )
- Wavelength Accuracy : ±1 nm
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Double Beam UV VIS Spectrophotometer TRDUV-604
- Monochromatic type : Czerny turner
- Focal length : 160 mm
- Wavelength Range : 190 to 1100nm
- Band Width : 2 nm
Double Beam UV VIS Spectrophotometer TRDUV-601
- Spectrum Bandwidth : 2 nm
- Wavelength Range : 190 to 1100 nm
- Monochromatic Type : Czerny-Turner
- Grating : 1600 lines/mm
Double Beam UV VIS Spectrophotometer TRDUV-602
- Spectrum Bandwidth : 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
- Wavelength Range : 190 to 1100 nm
- Monochromatic Type : Czerny-Turner
- Grating : 1600 lines/mm
Double Beam UV VIS Spectrophotometer TRDUV-603
- Monochromatic type : Czerny turner
- Focal length : 160 mm
- Wavelength Range : 190 to 1100 nm
- Band Width : 1.8 nm
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Single Beam UV VIS Spectrophotometer TRSUV-605
- Photometry : Single Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS Spectrophotometer TRSUV-606
- Photometry : Single Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-601
- Photometry : Split Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-602
- Photometry : Split Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-607
- Photometry : Single Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-608
- Photometry : Single Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-603
- Photometry : Split Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-604
- Photometry : Split Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Visible Spectrophotometer TRVS-601
- Photometry : Single beam
- Monochromatic Type : Littrow
- Focal Length : 160 mm
- Wavelength Setting : Manual Turn Knob
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Spectrophotometer TRNS-601
- Wavelength Range : 900 to 1700 nm
- Wavelength Accuracy : ±1 nm
- Wavelength Reproducibility : ≤1 nm
- Wavelength Scanning Interval Absorbance : 1 nm, 4 nm, 8 nm, 16 nm