Visible Spectrophotometer TRVS-601
Visible Spectrophotometer TRVS-601 is a compact benchtop device. The holographic blazed grating is monochromatic, with high wavelength accuracy, and low stray light. The wavelength ranges from 325 to 1000 nm with an accuracy of 2 nm and a spectrum bandwidth of 2 nm is measured using a microcomputer. It has a 7-inch multi-color touch-screen to view and set parameters. Its photometric value ranges from 0.0 to 100.0 % T, 0 to 1.999A, and 0 to 1999 C, with a ±0.5 % T accuracy.
| Photometry | Single beam |
|---|---|
| Monochromatic Type | Littrow |
| Focal Length | 160 mm |
| Wavelength Setting | Manual Turn Knob |
| Wavelength Range | 325 to1000 nm |
| Wavelength Accuracy | ± 2 nm |
| Wavelength Repeatability | ≤ 1 nm |
| Cuvette Holder Size | 10 mm |
| Photometric Range | 0.0 to 100.0% T, 0 to 1.999A, 0 to 1999C |
| Photometric Accuracy | ± 0.5% T |
| Photometric Repeatability | ≤ 0.2% T |
| Spectrum Bandwidth | 2 nm |
| Grating | 1200 lines/mm |
| Detector | Silicon Photocell |
| Stray Light | ≤ 0.1% ( at 360 nm NaNO2 ) |
| Noise | 100%(T) noise ≤ 0.3% (T), 0% (T) noise ≤ 0.2% (T) |
| Drift | ± 0.5% T/3 min |
| Power | AC220v±22v,50Hz± 1Hz, 80W |
| Packing Size | 580×460×340 mm |
| Weight | 0.1CBM, 14 Kg |
- The monochrome holographic discing diffraction has the advantages of high wavelength accuracy, good monochromaticity, and low stray light
- The intensity testing method now includes the parameter estimation and coefficient methods
- Touchscreen 7-inch multi-color display with a good human-computer interface
- Equipped with a microcomputer measurement system with high T-A alteration accuracy, involuntary adjustment of 0% T and 100% T, concentration factor setting, and direct reading of the concentration
- The T/A switchover is precise and automatic
- Quantification reading was taken with high accuracy, reproducibility, and stability
- The zero and full scales are automatically adjusted
- There is no need for a particle to protect the photoelectric sensor with automatic light gate technology
- This has a USB connection and huge storage capabilities, allowing it to store 30 concentration curves
- Sample compartment for vials ranging in size from 5 to 50mm
- Functions for direct concentration reading and concentration factor setting
- An RS232 port is provided
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Atomic Absorption Spectrophotometer TRAS-601
- Wavelength Range : 190 to 900 nm
- Wavelength Accuracy : £ ±0.5 nm
- Wavelength Repeatability : £ 0.3 nm (single direction)
- Spectrum Bandwidth : 0.2 nm, 0.4 nm, 0.7nm, 1.4 nm, 2.4 nm, 5.0 nm
Atomic Absorption Spectrophotometer TRAS-701
- Wavelength range : 190 to 900 nm
- Spectral bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
- Accuracy of the wavelength : ±0.15 nm
- Receptivity of the wavelength : ≤0.04 nm
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Micro Spectrophotometer TRMS-604
- Wavelength Range : 190 to 850 nm
- Wavelength Accuracy : ± 1 nm
- Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
- Repeatability : <± 0.5 nm
Micro Spectrophotometer TRMS-605
- Wavelength Range : 190 to 850 nm
- Wavelength Accuracy : ± 1nm
- Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
- Repeatability : <± 0.5 nm
Micro-Spectrophotometer TRMS-601
- Light Path : 1mm
- sample Volume : 1 to 2μL
- Detection Range : 190 to 850 nm
- Wavelength Range : 190 to 1100 nm
Micro-spectrophotometer TRMS-602
- Optical Path : 1/0.5/0.05 mm automatic conversion
- Optical Range : 190 to 1100 nm
- Sample Volume : 0.3 to 2.0 μl
- Light Source : Long-life Xenon lamp
Micro-spectrophotometer TRMS-603
- Wavelength scanning Range : 190 to 850 nm
- Wavelength Accuracy : ±1 nm
- Optical Path : 1/0.5/0.05 mm automatic conversion
- Optical Range : 190 to 1100 nm
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Energy Dispersion X-ray Fluorescence Spectrometer TRXS-601
- Analysis Principle : Energy-dispersive X-ray fluorescence analysis
- Element Measuring Range : Any element from Na(11)-U(92)
- Minimum Measuring Limit : Cd/Hg/Br/Cr/Pb≤2 ppm
- Sample Shape : Arbitrary size, any irregular shape
Fluorescence Spectrophotometer TRFS-601
- Exciting Optical Filters : Interface optical filter (10 nm bandwidth)
- Wavelength : 365 nm
- Emission Monochromatic : C-T diffraction grating (EM 200 to 900 nm )
- Wavelength Accuracy : ±1 nm
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Double Beam UV VIS Spectrophotometer TRDUV-604
- Monochromatic type : Czerny turner
- Focal length : 160 mm
- Wavelength Range : 190 to 1100nm
- Band Width : 2 nm
Double Beam UV VIS Spectrophotometer TRDUV-601
- Spectrum Bandwidth : 2 nm
- Wavelength Range : 190 to 1100 nm
- Monochromatic Type : Czerny-Turner
- Grating : 1600 lines/mm
Double Beam UV VIS Spectrophotometer TRDUV-602
- Spectrum Bandwidth : 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
- Wavelength Range : 190 to 1100 nm
- Monochromatic Type : Czerny-Turner
- Grating : 1600 lines/mm
Double Beam UV VIS Spectrophotometer TRDUV-603
- Monochromatic type : Czerny turner
- Focal length : 160 mm
- Wavelength Range : 190 to 1100 nm
- Band Width : 1.8 nm
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Single Beam UV VIS Spectrophotometer TRSUV-605
- Photometry : Single Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS Spectrophotometer TRSUV-606
- Photometry : Single Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-601
- Photometry : Split Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-602
- Photometry : Split Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-607
- Photometry : Single Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-608
- Photometry : Single Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-603
- Photometry : Split Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Single Beam UV VIS SpectrophotometerTRSUV-604
- Photometry : Split Beam
- Monochromatic Type : Czerny-Turner
- Focal Length : 160 mm
- Grating : 1200 lines/mm
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Spectrophotometer TRNS-601
- Wavelength Range : 900 to 1700 nm
- Wavelength Accuracy : ±1 nm
- Wavelength Reproducibility : ≤1 nm
- Wavelength Scanning Interval Absorbance : 1 nm, 4 nm, 8 nm, 16 nm