Biological Safety Cabinet TRBC-602
Biological Safety Cabinet TRBC-602 Is a closed working environment that can effectively protect against corrosion caused by corrosive substances and disinfectants. Digital display panels are used in all steel-framed workplaces. This includes UV lamps, fluorescent lights, and differential displays. There are HEPA filters and primary filters. HEPA filters contribute to a clean working environment. It is a sterilization method linked with safety functions. Discharges 100% of the airflow outside the cross-contamination.
| Number Of Colonies | ≤0.5pcs/dish hour (Φ90mm culture plate) |
|---|---|
| Average Wind Speed | 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s |
| Front Suction Wind Speed | 0.55m ± 0.025m/s (30% Efflux) |
| Noise | ≤65 dB(A) |
| Vibration Half Peak | ≤3 μm |
| Voltage | AC single-phase, 220 V/50 Hz |
| Maximum Power Consumption | 600 W |
| Weight | 250 Kg |
| Working Area W1×D1×H1 | 1340×650×620 mm |
| Overall Dimension W×D×H | 1500×800×2100 mm |
| High-Efficiency Filter Specification And Quantity | 1280×490×50×1, 820×380×70×1 |
| Specification And Quantity Of Fluorescent Lamp/Ultraviolet Lamp | 30W×2/30W×1 |
- It is built with air curtain isolation in mindBy discharging 100% of the airflow outside, negative pressure vertical laminar flow, no need to install pipes
- It prevents internal and external cross-contamination
- The glass door can be moved up and down, and it can be positioned in any direction
- It is simple to use and can be sterilized completely closed
- W0ith the prompting of the positioning height, limit alarm
- The work area's power output socket is equipped with a waterproof socket and a sewage interface for the operator's convenience
- A special filter installed at the exhaustion of air to control pollution emissions
- The working environment is made of high-quality stainless steel that is smooth, seamless, and corrosion-resistant
- It can be disinfected quickly and thoroughly, and it can resist corrosion from corrosive agents and disinfectants
- An LED LCD panel controls it
- Built-in UV lamp protection device, which can only turn on when the safety door is shutdown
- With a DOP detection port and a built-in differential pressure gauge, that tilts 10˚ by the human body design concept
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Biological Safety Cabinet TRBC-601
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
- Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
- Noise : ≤65 dB(A)
Biological Safety Cabinet TRBC-603
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
- Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
- Noise : ≤65 dB(A)
Biological safety cabinet TRBC-604
- The Average Wind Speed- Inner Side : 0.38 + -0.025m/s
- The Average Wind Speed- Middle : 0.26 + -0.025 m/S
- The Average Wind Speed-Inside : 0.35 + -0.025 m/s
- Air Tightness : <=10 – 6 m/S 500 Pa leakage rate
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Vertical Air Laminar Flow Cabinet TRVLC-601
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-602
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-603
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-604
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-605
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-606
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Horizontal Laminar flow cabinet TRHL-603
- Cleanliness Level : Class 100 @ ≥ 0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45 m/s (Fast and slow)
- Noise : ≤62dB (A)
Horizontal Laminar flow cabinet TRHL-604
- Cleanliness Level : Class 100 @ ≥ 0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45 m/s (Fast and slow)
- Noise : ≤62dB (A)
Horizontal Laminar flow cabinet TRHL-601
- Cleanliness Level : Class 100@≥0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45m/s (Fast and slow)
- Noise : ≤62dB(A)
Horizontal Laminar flow cabinet TRHL-602
- Cleanliness Level : Class 100@≥0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45m/s (Fast and slow)
- Noise : ≤62dB(A)
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Vertical and Horizontal Laminar Flow Cabinet TRVHC-602
- The Average Wind Speed : 0.25 to 0.45m/s (Speed two-speed)
- Noise : ≤62 dB
- Power Supply : AC, 220 V/50Hz
- MaximumPower Consumption : 800 W
Vertical and Horizontal Laminar Flow Cabinet TRVHC-601
- The Average Wind Speed : 0.25 to 0.45m/s(Speed two-speed)
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- MaximumPower Consumption : 300W