Vertical and Horizontal Laminar Flow Cabinet TRVHC-601
Vertical and Horizontal Laminar Flow Cabinet TRVHC-601material is stainless steel, and a wind volume adjustable fan system is used. Based on a one-dimensional system. It has a sliding glass door that allows for easy observation. The device prevents outside gas from entering the operating room, preventing a strange odor from entering. The range of illumination is 300LX.
| The Average Wind Speed | 0.25 to 0.45m/s(Speed two-speed) |
|---|---|
| Noise | ≤62dB |
| Power Supply | AC, 220 V/50Hz |
| MaximumPower Consumption | 300W |
| Illumination | ≥300LX |
| Number of Bacteria | ≤0.5per utensil. Hour(90mm utensil) |
| Half Ventilation Peak Value | ≤ 3μm(XYZ direction) |
| Efficient Filter Specifications And Quantities | 865×600×38×1/865×484×38×1 |
| Specification And Number Of Fluorescent Lamp Or UV Lamp Of Ultraviolet Lights | 20W×1/20W×1 |
| Suited Number | Single-Single |
| Dimension Of Working Area(W1×D1×H1) | 870×500×620mm |
| Overall Dimension W×D×H | 1050×760×1800mm |
| Weight | 150 Kg |
- The vertical closed bench effectively prevents outside gas from entering
- Able to operate area and prevents the slightly odd aroma
- A wind volume adjustable fan system
- A light-touch type switch and a dual-speed voltage regulation device
- the personalized design takes into account all of the user's requirements
- It uses a spring-type sliding door to allow the door to be geared in the desired position
- It is easier to use
- Filters and electric components can easily be exchanged by opening the front cover directly
- Use the LED panel to your advantage
- The stainless steel used for the workspace
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Vertical and Horizontal Laminar Flow Cabinet TRVHC-602
- The Average Wind Speed : 0.25 to 0.45m/s (Speed two-speed)
- Noise : ≤62 dB
- Power Supply : AC, 220 V/50Hz
- MaximumPower Consumption : 800 W
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Biological Safety Cabinet TRBC-601
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
- Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
- Noise : ≤65 dB(A)
Biological Safety Cabinet TRBC-602
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
- Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
- Noise : ≤65 dB(A)
Biological Safety Cabinet TRBC-603
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
- Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
- Noise : ≤65 dB(A)
Biological safety cabinet TRBC-604
- The Average Wind Speed- Inner Side : 0.38 + -0.025m/s
- The Average Wind Speed- Middle : 0.26 + -0.025 m/S
- The Average Wind Speed-Inside : 0.35 + -0.025 m/s
- Air Tightness : <=10 – 6 m/S 500 Pa leakage rate
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Vertical Air Laminar Flow Cabinet TRVLC-601
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-602
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-603
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-604
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-605
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-606
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Horizontal Laminar flow cabinet TRHL-603
- Cleanliness Level : Class 100 @ ≥ 0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45 m/s (Fast and slow)
- Noise : ≤62dB (A)
Horizontal Laminar flow cabinet TRHL-604
- Cleanliness Level : Class 100 @ ≥ 0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45 m/s (Fast and slow)
- Noise : ≤62dB (A)
Horizontal Laminar flow cabinet TRHL-601
- Cleanliness Level : Class 100@≥0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45m/s (Fast and slow)
- Noise : ≤62dB(A)
Horizontal Laminar flow cabinet TRHL-602
- Cleanliness Level : Class 100@≥0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45m/s (Fast and slow)
- Noise : ≤62dB(A)