Vertical Air Laminar Flow Cabinet TRVLC-601
Vertical Air Laminar Flow Cabinet TRVLC-601 is an airflow-closed bench, designed with a stainless steel working space and a sliding glass door. It is equipped with a UV lamp and a fluorescent lamp. The average wind speed ranges from 0.25 to 0.45 m/s. It has a single-single dimension and comes with a primary filter and a HEPA filter. Intended with a digital display, shows the liquid crystal interference. Its maximum power consumption is 400 W.
| The Average Wind Speed | 0.25 to 0.45m/s |
|---|---|
| Noise | ≤62dB |
| Power Supply | AC, 220 V/50Hz |
| Illumination | ≥300LX |
| Half Ventilation Peak Value | ≤ 3μm(XYZ direction) |
| Maximum Power Consumption | 400W |
| Number Of Bacteria | ≤0.5per utensil. Hour (90mm utensil) |
| Specification And Number Of Fluorescent Lamp Or UV Lamp Of Ultraviolet Lights | 20w×1/ 20w×1 |
| Dimension Of Working Area(W1×D1×H1) | 700×600×700mm |
| Overall Dimension (W×D×H) | 860×760×1760mm |
| Suited Number | single-single |
- The vertical airflow and closed bench effectively prevent outside gas from entering
- The ability to operate the area, as well as the distinctive smell from harming the human body
- A wind volume adjustable fan system, a light-touch type switch, and a dual-speed voltage
- A regulation device is used to maintain a suitable wind speed in the working area
- it uses a super-thin aluminum-frame clapboard-free high-efficiency air filter
- Which shrinks the static-pressure tank to the smallest possible size, reducing the outer case's size
- Filters and electric components can be easily exchanged by opening the front cover directly
- An LED panel powers it with liquid crystal interference
- The work surface is made of stainless steel
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Vertical Air Laminar Flow Cabinet TRVLC-602
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-603
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-604
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-605
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Vertical Air Laminar Flow Cabinet TRVLC-606
- The Average Wind Speed : 0.25 to 0.45m/s
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- Illumination : ≥300LX
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Biological Safety Cabinet TRBC-601
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
- Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
- Noise : ≤65 dB(A)
Biological Safety Cabinet TRBC-602
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
- Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
- Noise : ≤65 dB(A)
Biological Safety Cabinet TRBC-603
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
- Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
- Noise : ≤65 dB(A)
Biological safety cabinet TRBC-604
- The Average Wind Speed- Inner Side : 0.38 + -0.025m/s
- The Average Wind Speed- Middle : 0.26 + -0.025 m/S
- The Average Wind Speed-Inside : 0.35 + -0.025 m/s
- Air Tightness : <=10 – 6 m/S 500 Pa leakage rate
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Horizontal Laminar flow cabinet TRHL-603
- Cleanliness Level : Class 100 @ ≥ 0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45 m/s (Fast and slow)
- Noise : ≤62dB (A)
Horizontal Laminar flow cabinet TRHL-604
- Cleanliness Level : Class 100 @ ≥ 0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45 m/s (Fast and slow)
- Noise : ≤62dB (A)
Horizontal Laminar flow cabinet TRHL-601
- Cleanliness Level : Class 100@≥0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45m/s (Fast and slow)
- Noise : ≤62dB(A)
Horizontal Laminar flow cabinet TRHL-602
- Cleanliness Level : Class 100@≥0.5μM
- Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
- Average Wind Speed : 0.25 to 0.45m/s (Fast and slow)
- Noise : ≤62dB(A)
Blood refrigerators are specialized laboratory equipment designed to store blood and blood components under precise temperature conditions to ensure their viability and safety. These units are essential in hospitals, blood banks, research facilities, and laboratories where the preservation of blood products is critical.
Vertical and Horizontal Laminar Flow Cabinet TRVHC-602
- The Average Wind Speed : 0.25 to 0.45m/s (Speed two-speed)
- Noise : ≤62 dB
- Power Supply : AC, 220 V/50Hz
- MaximumPower Consumption : 800 W
Vertical and Horizontal Laminar Flow Cabinet TRVHC-601
- The Average Wind Speed : 0.25 to 0.45m/s(Speed two-speed)
- Noise : ≤62dB
- Power Supply : AC, 220 V/50Hz
- MaximumPower Consumption : 300W